4. Advanced SkLineScan Software Functions
Schäfter + Kirchhoff © 2014 • Line Scan Camera SK1024U3PD Manual (05.2014) • shared_AdvancedSyncCtrl(1)_AdvancedTriggerFct-SyncCtrlReg.indd (05.2014)
The basic synchronization function makes use of the trigger input LINE SYNC A. The trigger mode is determined by
the settings in the "Camera Control" dialog, e.g. LineStart (1) or ExposureStart (4).
Advanced trigger functions are provided by combining LINE SYNC A with a second trigger input LINE SYNC B. The
operation mode is controlled by the entries in the Sync Control Register (SCR).
Use control commands to write to or to read from the Sync
Control Register:
Yppp<CR> set sync control
with ppp = 0...255 (decimal)
Return value: 0 = OK; 1 = not OK
I29<CR> return sync control
Return value: SyC:yyyyy (5-digits integer value as ASCII)
Advanced Trigger Functions and Sync Control Register Settings
Basic synchronization function, 'Camera Control' dialog settings are valid
A
Detection of direction
B
,
C
,
D
,
E
Trigger pulses are valid only in one direction, trigger pulses in the other direction are ignored
B
Trigger on 4 edges
D
,
E
Suppression of machine-encoded jitter, programmable hysteresis for trigger control
E
Sync Control Register (SCR) SyC7 SyC6 SyC5 SyC4 SyC3 SyC2 SyC1 SyC0
default x x x x x x 0 0
pixel #1 data = external trigger input states x x x x x x 0 1
pixel #1 data = Linecounter (8 bit) x x x x x x 1 0
pixel #1, #2 data = ext. trigger states (3 bit) +
line counter (13 bit)
x x x x x x 1 1
ExSOS and Sync at LINE SYNC A (Mode5) x x x x x 0 x x
ExSOS at LINE SYNC B,
Sync at LINE SYNC A (Mode5)
x x x x x 1 x x
Jitter Hysterese off x x x 0 0 x x x
Jitter Hysterese 4 x x x 0 1 x x x
Jitter Hysterese 16 x x x 1 0 x x x
Jitter Hysterese 64 x x x 1 1 x x x
Sync 1x Enable x x 0 x x x x x
Sync 4x Enable x x 1 x x x x x
Sync up Enable / down disable x 0 x x x x x x
Sync up/down Enable x 1 x x x x x x
Sync Control Disable 0 x x x x x x x
Sync Control Enable 1 x x x x x x x
128 64 32 16 8 4 2 1
Example:
Y232
ppp = 232(dec) = 11101000(bin)
new SCR value: 11101000
E
4.2 Advanced Synchronization Control
For diagnostic purposes, the
present state of external trigger
inputs (LINE SYNC A, LINE
SYNC B, FRAME SYNC) or the
internal line counter can be output
instead of pixel #1 and/or pixel #2
data.
SCR Pixel #1 Data (lowByte) Pixel #2 Data (lowByte)
xxxxxx00 intensity intensity
xxxxxx01
D7 = FRAME SYNC
D6 = LINE SYNC A
D5 = LINE SYNC B
D4 ... D0 = 0
intensity
xxxxxx10 internal line counter (8 bit) intensity
xxxxxx11
D7 = FRAME SYNC
D6 = LINE SYNC A
D5 = LINE SYNC B
D4 ... D0 = line counter (bit 12 ... 8)
internal line counter (bit 7 ... 0)
4. Advanced SkLineScan Software Functions