Interface
1MC
Line scan
camera Pixels
Order code
SK512SD
1
512
Pixel fre-
quency,
max.
Line
frequency,
max.
2
10 MHz
3
18.45 kHz
2
3
MC
MC
4
5
MC
RGB
SK1024SD
SK2048JRI
1024
2048
SK2048SD
SK3072JRC
2048
2 x 1536
10 MHz
5 MHz
9.48 kHz
2.37 kHz
10 MHz
6 MHz
4.80 kHz
1.85 kHz
Video
signal
Pixel
size
4
1/1-10 V
5
14 x 14 μm
Active
length
Anti-
Bloom
6
7.17 mm
7
x
Integr.
Ctrl.
Dynamic
range
(RMS)
8
x
9
1:1500
Power
supply
Camera
casing
10
+5V, +12V, -12V
11
RA1
1/1-10 V
1/1-10 V
14 x 14 μm
14 x 14 μm
1/1-10 V
1/1-4 V
14 x 14 μm
12 x 14 μm
14.30 mm
28.70 mm
x
-
28.70 mm
28.70 mm
x
-
x
x
1:1500
1: 500
x
-
1:1500
1: 500
+5V, +12V, -12V
+5V, +12V, -12V
RA1
RA2
+5V, +12V, -12V
+5V, +12V, -12V
RA2
RA2
Lens
thread
12
C-Mount
C-Mount
M40x0.75
M40x0.75
M40x0.75
B /W
analog_ZK.indd • Page 28
Kieler Str. 212, 22525 Hamburg, Germany
• Tel: +49 40 85 39 97-0 • Fax: +49 40 85 39 97-79 • [email protected] • www.SuKHamburg.com28
11-2014 E
Analog
In order to function, an analog line scan camera
needs a control signal or Clock (pixel frequency
maximum of 10 MHz) and SOS (Start Of Scan)
as well as a voltage supply of +5 V or +/-12 V.
The output of video data from an analog line scan
camera is a variable voltage in the range from
0−10 V. Before the video data can be stored or
used in a computer, a Line Scan Grabber SK9190
*
More than 20 other analog line scan cameras are available and details can be supplied on request
FFL
Pixel 1
M3 (4x)
depth 6.5 mm
62
M40x0.75
2.5
6
34
Ø42
6.5
Pixel 1
M3 (4x)
depth
6.5 mm
61
C-Mount
Ø36
32.5
Ø54
14
6
2.5
Back view: analog line scan camera
Manual gain/off set
adjustment is performed
using the trimming
resistors
P1
Gain adjustment
P2
Offset adjustment
C
D
P1
P2
nc
GND
(+12 V) +15 V
+5 V
(-12 V) -15 V
SOS +
MCLK +
Shielding
GND
LVAL-
LVAL+
CCLK-
CCLK+
SOS-
MCLK -
o 9
o 10
o 11
o 12
o 13
o 14
o 15
1 o
2 o
3 o
4 o
5 o
6 o
7 o
8 o
female 15-pin D-SUB
D
Video Out
BNC
connector
C
Pin assignment
Line Scan Grabber
for analog line scan
cameras: PCI bus,
preprocessing on-board,
shading correction, ROI,
thresholding, external
synchronization.
Order Code Operating System
SK91PCI-WIN Windows 7/XP
SK91PCI-LX Linux
SK91PCI-LV LabVIEW
Software
Line Scan
Grabber
SK9190
Tab le 1
Line Scan Cameras
from 512 to 2048 pixels,
monochrome or color
Analog
or an A/D converter module SK9158 is used to
digitalize the signal.
The software package SK91PCI-WIN (..-LX)
for Windows 7/XP (Linux) contains the display
and control program SkLineScan
®
that allows
use of the camera ‘out-of-the-box’. The Software
Development Kit (SDK) enables customized
program applications to be developed.
see Table 1,
lines 1-4
see Table 1,
line 5
Color
3 x 1024 pixels
monochrome
1.0
0.0
400 600
800 1000
Spectral range
512 -5150 pixels
SK9190
PCI bus
PC
with PCI slot
Analog
Connections and controls
Input: Clock = pixel frequency, max. 10 MHz
SOS = Start Of Scan signal
Output: analog video (0−10 V)
Relay diagram of analog line scan camera
Line scan signal using the software
SK91PCI-WIN
FFL
Video OUT analog
BNC connector
Control
D-SUB, 15-pin, RS422 IN
Voltage
+5 V, +/- 12 V (+/- 15 V)
Gain,Offset
Potentiometer on
camera back
1. Offset: Without the sensor being illuminated,
offset is adjusted using the potentiometer
P2
to set the signal to 0 volt.
2. Gain: The sensor is slightly over-illuminated
and the maximum output voltage of the camera
is specified using
P1
, so that the maximum
level remains just visible.
The maximum output voltage is set to 1.1 V by
default but, upon request, an output of up to 10
volts can be factory-preset.
Gain/Offset adjustment
Connections/controls
Page
Line scan camera . . . . . . . . . . . . . . . . . . . . . . . 12, 13, 32
Lenses, focus adapters, extension rings . . . . . . . . . . 39−43
Mounting brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Line Scan grabber SK9190 . . . . . . . . . . . . . . . . . . . . . . 28
Cables: SK9017.3 FF . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Software: SK91PCI-WIN,-LV, SK91PCI-LX . . . . . . . . . . 10
Components
Features
Extern al synchroni zation X
Shading correction X
Windowing (ROI) X
Thresholding X
Windows, LabVIEW, Linux SK91PCI-WIN, -LV, -LX
Interface:
Line Scan Camera
Illumination
Line Scan Grabber
SK9190 for PCI bus
1
2
3
1
2
3
RA1 RA2
Lens mount: C-Mount
Seat for bracket: Ø36 mm
Flange focal length: FFL = 17.5 mm
Lens mount: M40x0.75
Seat for bracket: Ø42 mm
Flange focal length: FFL = 19.5 mm
Ø54